[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[AWIPS #TSM-138530]: AWIPS GFS LAMP Ceiling and Visibility Question



> AWIPS/UCAR,
> 
> I was looking at the GFS LAMP2p5 model output data for both ceiling and
> visibility. There should be at least 25 hours of data in the inventory but
> only 2 hours of data will actually plot a 19Z and 20Z image.
> 
> Using the GFS LAMP Convective and Lightning data there are 25 hours of data
> available to the user. Am I missing something?

Hello,

Looking into this, it looks like there weren't any specific purge rules for GFS 
LAMP data, so it was using the default of 2 versions which was why you were 
only seeing 2 hours worth of data. I've added a new purge rule specific for GFS 
LAMP to keep 25 versions (hours). Within the next 24 hours you should be seeing 
more data.


Thanks,

Tiffany Meyer
AWIPS Lead Software Engineer
UCAR-Unidata

If you're interested, please feel free to fill out a survey about the support 
you receive:  
https://docs.google.com/forms/d/e/1FAIpQLSeDIkdk8qUMgq8ZdM4jhP-ubJPUOr-mJMQgxInwoAWoV5QcOw/viewform

Ticket Details
===================
Ticket ID: TSM-138530
Department: Support AWIPS
Priority: Normal
Status: Open
===================
NOTE: All email exchanges with Unidata User Support are recorded in the Unidata 
inquiry tracking system and then made publicly available through the web.  If 
you do not want to have your interactions made available in this way, you must 
let us know in each email you send to us.