Re: [thredds] cannot figure out why WCS won't work with this FMRC

  • Subject: Re: [thredds] cannot figure out why WCS won't work with this FMRC
  • From: John Caron <caron@xxxxxxxxxxxxxxxx>
  • Date: Fri, 20 Apr 2012 08:07:39 -0600
On 4/19/2012 6:54 PM, John Maurer wrote:
Thanks again, Jonathan! That fixed things up nicely: WCS works now.
Cheers,
John Maurer

P.S. For Unidata: The TDS WCS documentation (http://www.unidata.ucar.edu/projects/THREDDS/tech/reference/WCS.html) states that the Z axis must also be regularly spaced. This doesn't seem to be true since our depths are not regularly spaced: -5500, -5000, -4500, -4000, -3500, -3000, -2500, -2000, -1750, -1500, -1400, -1300, -1200, -1100, -1000, -900, -800, -700, -600, -500, -400, -300, -250, -200, -150, -125, -100, -75, -50, -30, -20, -10, -5. Might need to update the documentation on that page. Thanks.

thanks, John, I will correct that page.