Due to the current gap in continued funding from the U.S. National Science Foundation (NSF), the NSF Unidata Program Center has temporarily paused most operations. See NSF Unidata Pause in Most Operations for details.
Hi John, I see your point about coordinate variables. However it would be nice to be able to say "aggregate over all non-coordinate variable". Unless there's something I'm missing, I would have thought that this was a very common case. Thanks, Jon On 03/10/06, John Caron <caron@xxxxxxxxxxxxxxxx> wrote:
Hi Jon: How do you distinguish between variables that should be aggregated and those that shouldnt? for example, often adding a time dimension to the coordinate variables screws things up for some software. jdb@xxxxxxxxxxxxxxxxxxxx wrote: >Hi all, > >I'm creating aggregations of NetCDF files by aggregating on a new time >dimension, whose values come from the names of the files. My .ncml file looks >like this: > ><netcdf xmlns="http://www.unidata.ucar.edu/namespaces/netcdf/ncml-2.2"> > <aggregation dimName="time" type="joinNew"> > <variableAgg name="ICEC"/> > <variableAgg name="ICETK"/> > <variableAgg name="M"/> > <variableAgg name="...etc"/> > <scan location="C:/data/FOAM_one/" suffix=".nc" >dateFormatMark="FOAM_#yyyyMMdd.HH" /> > </aggregation> ></netcdf> > >It's a bit tedious to have to specify explicitly all the variables I want to >aggregate. I want to aggregate all variables so I would like to be able to >have: > ><netcdf xmlns="http://www.unidata.ucar.edu/namespaces/netcdf/ncml-2.2"> > <aggregation dimName="time" type="joinNew"> > <variableAgg name="*"/> > <scan location="C:/data/FOAM_one/" suffix=".nc" >dateFormatMark="FOAM_#yyyyMMdd.HH" /> > </aggregation> ></netcdf> > >or something like that. Is this possible? If I try that, no variables get >aggregated (when I open a GridDataset, there is no time dimension). > >Thanks in advance, >Jon > >---------------------------------------------------------------- >This message was sent using IMP, the Internet Messaging Program. > >============================================================================== >To unsubscribe netcdf-java, visit: >http://www.unidata.ucar.edu/mailing-list-delete-form.html >============================================================================== > >
-- -------------------------------------------------------------- Dr Jon Blower Tel: +44 118 378 5213 (direct line) Technical Director Tel: +44 118 378 8741 (ESSC) Reading e-Science Centre Fax: +44 118 378 6413 ESSC Email: jdb@xxxxxxxxxxxxxxxxxxxx University of Reading 3 Earley Gate Reading RG6 6AL, UK -------------------------------------------------------------- ============================================================================== To unsubscribe netcdf-java, visit: http://www.unidata.ucar.edu/mailing-list-delete-form.html ==============================================================================
netcdf-java
archives: