[CONDUIT #RFO-442890]: GFS upgrade



Hi Carissa,

At about 22:51:53 UTC yesterday, December 23, lead.unidata.ucar.edu's
ability to access 140.90.101.93 stopped.  The indications from 
'notifyme -vl- -f CONDUIT -h 140.90.101.93' are that the firewall
change that had been made to allow lead.unidata.ucar.edu to access
the LDM running on 140.90.101.93 was undone.  Until the firewall
block has been removed, our testing of the CONDUIT feed from 140.90.101.93
will continue to fail.

Can you ask your network folks to restore the firewall rule that
allows lead.unidata.ucar.edu (IP address 128.117.149.100) to
access the LDM (port 388) on 140.90.101.93?  Thanks in advance!

Cheers,

Tom
--
****************************************************************************
Unidata User Support                                    UCAR Unidata Program
(303) 497-8642                                                 P.O. Box 3000
address@hidden                                   Boulder, CO 80307
----------------------------------------------------------------------------
Unidata HomePage                       http://www.unidata.ucar.edu
****************************************************************************


Ticket Details
===================
Ticket ID: RFO-442890
Department: Support CONDUIT
Priority: Normal
Status: Closed