[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[CONDUIT #WWT-483675]: Fire weather grids - pattern



Hi Kevin,

re:
> I saw the announcement for the fire weather grids on CONDUIT in the
> September 2011 Unidata wrap-up.

We also announced the addition in the address@hidden and
address@hidden email lists.  Did you not see those
announcements?

re:
> I did not see a link to a LDM/IDD pattern to weed out these grids.
> Can you please let me know what this pattern is?

All Fire Weather products contain 'firewxnest' in their LDM/IDD Product
IDs.  What you need to do is fashion ldmd.conf REQUEST line(s) that
ask for everything but products with 'firewxnest' in the Product ID.
Exactly what your REQUEST(s) would look like will depend on what they
contain currently.

The best way to come up with the pattern that you want is to use the
LDM 'notifyme' command... use the '-p' option to test your patterns
and then incorporate the one(s) that suite you best in your ldmd.conf
REQUEST line(s).


Cheers,

Tom
--
****************************************************************************
Unidata User Support                                    UCAR Unidata Program
(303) 497-8642                                                 P.O. Box 3000
address@hidden                                   Boulder, CO 80307
----------------------------------------------------------------------------
Unidata HomePage                       http://www.unidata.ucar.edu
****************************************************************************


Ticket Details
===================
Ticket ID: WWT-483675
Department: Support CONDUIT
Priority: Normal