Unidata - To provide the data services, tools, and cyberinfrastructure leadership that advance Earth system science, enhance educational opportunities, and broaden participation. Unidata
         
  advanced  
 

Re: A disturbing lack of data

Kevin & Ben,

>Date: Wed, 12 May 2004 15:53:57 +0000 (GMT)
>From: "Kevin R. Tyle" <ktyle@xxxxxxxxxxxxxxxx>
>To: Ben Cotton <bcotton@xxxxxxxxxx>
>Subject: Re: A disturbing lack of data

The above message contained the following:

> We find a lot of messages in our logs this morning which look
> like this:

Allow me to interpret.

> May 12 15:18:05 striker2 anvil(feed)[27191]: topo:  anvil.eas.purdue.edu NLDN

An upstream LDM on Striker2 was feeding NLDN data to Anvil.

> May 12 15:29:16 striker2 anvil(noti)[27462]: Starting Up(6.0.14/5): 
> 20040512202823.588 TS_ENDT {{NLDN,  ".*"}}
> May 12 15:29:16 striker2 anvil(noti)[27462]: topo:  anvil.eas.purdue.edu NLDN

An upstream LDM-5 process on Striker2 was started in response to a
NOTIFYME request from Anvil.  The start-time for the data is 2004-05-12
20:28:23.588 UTC, which is about FIVE HOURS IN THE FUTURE!

Is there something wrong with the clock on Anvil?

NOTE: The notifyme(1) program uses LDM-5 protocols rather than LDM-6
protocols.

> May 12 15:34:46 striker2 anvil(noti)[27462]:
> nullproc5(anvil.eas.purdue.edu): RPC: Unable to receive

The upstream LDM-5 on Striker2 was unable to to send a do-nothing
NULLPROC message to its downstream LDM-5 counterpart on Anvil.

> May 12 15:38:06 striker2 anvil(feed)[27684]: up6.c:331: Starting 
> Up(6.0.14/6): 20040512193713.933 TS_ENDT {{NLDN, ".*"}}
> May 12 15:38:06 striker2 anvil(feed)[27684]: topo:  anvil.eas.purdue.edu NLDN

An upstream LDM-6 process on Striker2 was started in response to a
FEEDME request on Anvil.  The start-time for the data is 2004-05-12
19:37:13.933 UTC, which is about FOUR HOURS IN THE FUTURE!

> May 12 15:38:06 striker2 anvil(feed)[27191]: up6.c:288: nullproc_6() failure 
> to anvil.eas.purdue.edu: RPC: Unable to receive; errno = Connection reset by 
> peer
> May 12 15:38:12 striker2 rpc.ldmd[24368]: child 27191 exited with status 5

The upstream LDM-6 process on Striker2 was unable to send a do-nothing
NULLPROC message to its downstream LDM-6 counterpart on Anvil.  The
connection was closed and the upstream LDM-6 process on Striker2
terminated.

Questions:

    1.  Are the times in Striker's logfile correct?  They should be
        UTC.

    2.  Is there something wrong with the clock on Anvil?

Regards,
Steve Emmerson

 
 
  Contact Us     Site Map     Search     Terms and Conditions     Privacy Policy     Participation Policy
 
National Science Foundation (NSF) UCAR Community Programs   Unidata is a member of the UCAR Community Programs, is managed by the University Corporation for Atmospheric Research, and is sponsored by the National Science Foundation.