>From: "Earle A. Ripley" <address@hidden> >Organization: University of Saskatchewan >Keywords: 199907161713.LAA02124 XCD-750 Earle, >I followed your instructions and yes the SCHEMA was an old one. After making >your changes I did get the following message, however:-- > >"maksfc - unable to make id file ISFCDEC.IDT" > >I'm still not sure if any data is going into the md files. Do you have a REDIRECTion for *.IDT files? If so, is it valid? If yes, is the drive to which these kind of files are to be written writable? The message looks like the surface decoder is trying to write to the above file and is not allowed. >Should there be >an entry in the ROUTE table when new MD data comes in? Not for XCD. The routing table, ROUTE.SYS, is not used by the XCD decoders at all. >With regard to the Menu System, I have deleted the appropriate VIRT files so >that is working okay now. Good. I'm glad to hear it. Tom