[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[LDM #HTX-391676]: radar processing box with problems



Gerry,

[This explains the second part of your question.]

Because you have three pqact(1) processes processing radar data, you could 
create three symbolic links to the actual pqact(1) configuration-file:

$ cd etc
$ ln -s pqact.gempak_craft.tamu.conf pqact.gempak_craft.tamu.1.conf
$ ln -s pqact.gempak_craft.tamu.conf pqact.gempak_craft.tamu.2.conf
$ ln -s pqact.gempak_craft.tamu.conf pqact.gempak_craft.tamu.3.conf

Then, modify the pqact(1) EXEC entries in the LDM configuration file to 
reference the symbolic links:

EXEC "pqact -vf NEXRAD2 -p K[AB].. etc/pqact.gempak_craft.tamu.1.conf"
EXEC "pqact -vf NEXRAD2 -p K[CD].. etc/pqact.gempak_craft.tamu.2.conf"
EXEC "pqact -vf NEXRAD2 -p K[EFG].. etc/pqact.gempak_craft.tamu.3.conf"

Regards,
Steve Emmerson

Ticket Details
===================
Ticket ID: HTX-391676
Department: Support LDM
Priority: Normal
Status: Closed


NOTE: All email exchanges with Unidata User Support are recorded in the Unidata inquiry tracking system and then made publicly available through the web. If you do not want to have your interactions made available in this way, you must let us know in each email you send to us.