On 4/19/2012 6:54 PM, John Maurer wrote:
Thanks again, Jonathan! That fixed things up nicely: WCS works now.
Cheers,
John Maurer

P.S. For Unidata: The TDS WCS documentation (http://www.unidata.ucar.edu/projects/THREDDS/tech/reference/WCS.html) states that the Z axis must also be regularly spaced. This doesn't seem to be true since our depths are not regularly spaced: -5500, -5000, -4500, -4000, -3500, -3000, -2500, -2000, -1750, -1500, -1400, -1300, -1200, -1100, -1000, -900, -800, -700, -600, -500, -400, -300, -250, -200, -150, -125, -100, -75, -50, -30, -20, -10, -5. Might need to update the documentation on that page. Thanks.

thanks, John, I will correct that page.

_______________________________________________
thredds mailing list
address@hidden
For list information or to unsubscribe, visit: http://www.unidata.ucar.edu/mailing_lists/



NOTE: All email exchanges with Unidata User Support are recorded in the Unidata inquiry tracking system and then made publicly available through the web. If you do not want to have your interactions made available in this way, you must let us know in each email you send to us.