Hi Greg,
re:
> Hmm. I tried imgremap on channel 4 IR and again ended up with BRIT.
I just ran:
IMGREMAP SOUTH/SH MYDATA/IMAGES.3010 TIME=19:58:00 LATLON=-17.5 82.5 PRO=RECT
RES=1 SIZE=3000 3000 SSIZE=ALL BAND=4
(to make sure that the source of the IMGREMAP was a full resolution image).
I then displayed the image and interrogated it:
IMGDISP MYDATA/IMAGES.3010 MAG=-4
Beginning Image Data transfer, bytes= 564928
IMGDISP: loaded frame 11
IMGDISP: done
IMGPROBE MODE=N
Image Name Day Nominal Time Scan Time Band
---------------- ------- ------------ --------- ----
MYDATA/IMAGES.3010 5 Sep 08249 19:58:00 MISSING 4
File Nominal Image RAW TEMP BRIT
Lat/Lon Line/Element Line/Element K
-8:58:47 / 82:55:22 552/ 1452 9053/ 9953 123 268.50 123
IMGPROBE: Done
If your listing doing the same sort of thing does _not_ have TEMP as one of
the available units, I would suspect the manner in which your local, single
band copy was made.
Cheers,
Tom
****************************************************************************