[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[McIDAS #QFU-969979]: Retaining calibrated units after imgremap



Hi Greg,

re:
> Hmm. I tried imgremap on channel 4 IR and again ended up with BRIT.

I just ran:

IMGREMAP SOUTH/SH MYDATA/IMAGES.3010 TIME=19:58:00 LATLON=-17.5 82.5 PRO=RECT 
RES=1 SIZE=3000 3000 SSIZE=ALL BAND=4

(to make sure that the source of the IMGREMAP was a full resolution image).

I then displayed the image and interrogated it:

IMGDISP MYDATA/IMAGES.3010 MAG=-4
Beginning Image Data transfer, bytes= 564928
IMGDISP: loaded frame  11
IMGDISP: done
 
IMGPROBE MODE=N

     Image Name           Day      Nominal Time   Scan Time    Band
  ----------------      -------    ------------   ---------    ----
  MYDATA/IMAGES.3010   5 Sep 08249   19:58:00      MISSING        4

                        File     Nominal  Image     RAW     TEMP    BRIT
       Lat/Lon      Line/Element  Line/Element               K
-8:58:47  / 82:55:22   552/ 1452    9053/ 9953       123    268.50    123

IMGPROBE: Done

If your listing doing the same sort of thing does _not_ have TEMP as one of
the available units, I would suspect the manner in which your local, single
band copy was made.

Cheers,

Tom
****************************************************************************
Unidata User Support                                    UCAR Unidata Program
(303) 497-8642                                                 P.O. Box 3000
address@hidden                                   Boulder, CO 80307
----------------------------------------------------------------------------
Unidata HomePage                       http://www.unidata.ucar.edu
****************************************************************************


Ticket Details
===================
Ticket ID: QFU-969979
Department: Support McIDAS
Priority: Normal
Status: Closed