[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[IDV #ANC-313982]: related to 3d grid datasources



> Actually the same issues also apply for times tab too.I will try to handle
> those issues may be first by writing a plugin for insat3d sounder profile
> output then will try to see how this can be used in core idv code.
> I hope you understand. I am really caught up in lots of other work.
> Meanwhile another query can we run idv in imageserver mode as a service on
> linux in /etc/init.d which starts at system startup.
> Ghansham

Ghansham,
     I think the RAMADDA server does something similar to this. 


Yuan 
> 
> address@hidden> wrote:
> > Ghansham,
> >
> > We confirm the problems you describe. We will have to put it on the to do
> list, unless you would like to provide us a fix. :-)
> >
> > Best Wishes,
> >
> > Unidata IDV Support
> >
> >> R/sir
> >>
> >> I think this is more of a design issue or I am ignorant. Can we select a
> >> set of pressure levels that aren't contiguous from data selector
> component.
> >> I tried pressing control key to select non contiguous levels. I am using
> >> 4.1u1. Another one is that inside geogrid code, the flatfield is made
> >> corresponding to all pressure levels when any one pressure level is
> >> selected to allow user to cycle through levels but I feel this is
> >> inefficient and wastage of memory for a sample test case like this.
> >> Lets suppose if a user wants to load grids for 4 different pressure
> levels
> >> in a 4 pane display he shall be creating four flatfields using all
> pressure
> >> levels. Even if user wants to load all pressure levels, he can do by
> >> choosing "All Levels" from levels data selection component. Am I able
> >> communicate clearly?
> >> Regards
> >> Ghansham
> >>
> >>
> >
> >
> > Ticket Details
> > ===================
> > Ticket ID: ANC-313982
> > Department: Support IDV
> > Priority: Normal
> > Status: Open
> >
> >
> 
> 


Ticket Details
===================
Ticket ID: ANC-313982
Department: Support IDV
Priority: Normal
Status: Closed


NOTE: All email exchanges with Unidata User Support are recorded in the Unidata inquiry tracking system and then made publicly available through the web. If you do not want to have your interactions made available in this way, you must let us know in each email you send to us.