[IDV #RWC-894290]: IDV v2.9u4: Computing surface temperature advection from NAM analysis
- Subject: [IDV #RWC-894290]: IDV v2.9u4: Computing surface temperature advection from NAM analysis
- Date: Mon, 09 May 2011 10:28:23 -0600
> Full Name: Dave Dempsey
> Email Address: address@hidden
> Organization: San Francisco State University
> Package Version: 2.9u4 build date:2011-03-02 08:14 UTC
> Operating System: Mac OS X
> Hardware: Java: home:
> /System/Library/Java/JavaVirtualMachines/1.6.0.jdk/Contents/Home version:
> 1.6.0_24 j3d:1.5.2 fcs (build4)
> Description of problem: Creating display: Omni Control
> visad.SetException: visad.SetException: Gridded3DSet.valueToGrid:
> ManifoldDimension must be 3
> Gridded3DSet.valueToGrid: ManifoldDimension must be 3
>
> I'm trying to calculate surface temperature advection from the latest NAM 40
> km analysis, using the Horizontal Advection formula. I specify temperature @
> height above ground as my scalar field and u- and v-components of wind
> @height above ground as the wind components. (The temperature is probably at
> 2 meters above ground, while the wind components are 10 meters above ground,
> probably. I wonder if this poses a problem.)
>
Hi Dave,
The problem here is the difference in the height, the advection formula in
the derived does not work in this case.
You can add a local formula to do this:
def surfaceHorizontalAdvection(aFF, uFF, vFF):
udtdx=GridMath.multiply(GridMath.ddx(aFF),uFF);
vdtdy=GridMath.multiply(GridMath.ddy(aFF),vFF);
advgrid=GridMath.add(udtdx,vdtdy);
return advgrid.negate();
I tested this in my machine and worked. I will probably make some changes in
the source code, so you will not need to do this in the future.
Yuan
> When I click on the Create Display button, I get the error message above.
>