[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[IDV #KUK-524844]: false temperature reading from adde.eumetsat.int



Hi HP-

> Full Name: HansPeter Roesli
> Email Address: address@hidden
> Organization: EUMETSAT
> Package Version: 2.7u2 build date:@DATE@
> Operating System: Linux
> Hardware: Java: home: /home/user/IDV_2.7u2/jre version: 1.6.0_13 j3d:1.5.2 
> fcs (build4)
> Description of problem: HI
> 
> I note that build of 26 and 27 Sep show wrong temperature values for data 
> from adde.eumetsat.in and the SSEC servert. Build of 18 Sep that still 
> happens to be on my Vista PC shows correct temperature values. Something must 
> have gone wrong on 26 Sep or 1-2 days earlier.

Thanks for catching this.  It will be fixed in the next nightly build.
 
> from a marvellous early autumn (sorry - fall), HP

from an equally marvellous autumn day in Boulder,

Don

Ticket Details
===================
Ticket ID: KUK-524844
Department: Support IDV
Priority: Normal
Status: Open


NOTE: All email exchanges with Unidata User Support are recorded in the Unidata inquiry tracking system and then made publicly available through the web. If you do not want to have your interactions made available in this way, you must let us know in each email you send to us.