[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[GEMPAK #WWZ-991406]: GEMPAK 5.9.3



> Steve
> 
> Thank you for your response. I have only now started looking at the
> examples. Essentially I have two routines, one that reads from an existing
> GEMPAK grid file and one that writes to one.
> 
> So I am looking to modify calls like
> 
> in_bdta, gd_opnf, gd_rdat, and gd_wpgd

Keep in_bdta.

All programs which use the grid diagnostics MUST call DG_INTL as shown in the 
examples.

Steve Chiswell
Unidata User Support


> 
> In my writing routine, I incorporated DG_NWDT, DG_INXT but was unable to get
> past the compile stage...
> 
> Thanks
> --
> Dr. Michael  Dickinson
> Senior Research Scientist
> Accurate Environmental Forecasting, Inc.
> 165 Dean Knauss Dr.
> Narragansett, RI 02882
> 401.788.9031 (voice)
> 401.788.9034 (fax)
> http://www.accufore.com
> 
> ----- Original Message -----
> From: "Unidata GEMPAK Support" <address@hidden>
> To: <address@hidden>
> Cc: <address@hidden>
> Sent: Wednesday, November 08, 2006 4:38 PM
> Subject: [GEMPAK #WWZ-991406]: GEMPAK 5.9.3
> 
> 
> > Michael,
> >
> > I put together an example of a routine that handles writing of a grid (eg
> > for
> > porting from gd_wpgd) that you might find useful. See:
> > http://www.unidata.ucar.edu/software/gempak/GEMPAK5.9/newgrid_example.tar.gz
> >
> > This routine creates a new grid file through GD_CREF which you do not need
> > if you
> > are using an existing grid file with GD_OPNF.
> >
> > Steve Chiswell
> > Unidata User Support
> >
> >
> >
> >> I have read through the GEMPAK 5.9.3 migration document
> >> (http://www.unidata.ucar.edu/software/gempak/GEMPAK5.9/GEMPAK_Grid_library_upgrade.html)
> >> but it is still not clear to me how to make the changes I need. I have a
> >> number of Fortran routines that read from GEMPAK data files using
> >> in_bdta, gd_opnf, gd_wpgd that I (clearly) need to replace but it is not
> >> clear to me how best to fulfill that goal.
> >>
> >>
> >> --
> >> Dr. Michael  Dickinson
> >> Senior Research Scientist
> >> Accurate Environmental Forecasting, Inc.
> >> 165 Dean Knauss Dr.
> >> Narragansett, RI 02882
> >> 401.788.9031 (voice)
> >> 401.788.9034 (fax)
> >> http://www.accufore.com
> >>
> >>
> >
> >
> > Ticket Details
> > ===================
> > Ticket ID: WWZ-991406
> > Department: Support GEMPAK
> > Priority: High
> > Status: Closed
> >
> 
> 
> 


Ticket Details
===================
Ticket ID: WWZ-991406
Department: Support GEMPAK
Priority: High
Status: Closed