Hi Pat,

you wrote the following to Pete Pokrandt/gembud mail list:
>I just checked the MU data directory again, and imagery began arriving
>just this morning at 9:12 am.

My impression after reading your email to Pete and the gembud list is that
the images you are referring to are different from the ones that Pete is
referring to:

- Pete was referring to the satellite images in the IDD NIMAGE datastream.
  Those images are the ones broadcast by the NWS in NOAAPort and relayed
  by us as the NIMAGE feed in the IDD.  Those images should have been
  included in the IDD with no interruption other than when NOAA switched
  to the use of GOES-13 for GOES-East surveillance.

- the GOES-East image sectors in Unidata-Wisconsin datastream (IDD feedtype
  UNIWISC (aka MCIDAS)) were also being created and sent right along, but the
  Product IDs for the GOES-East products were not what they should have
  been (i.e., UNKSAT instead of GOES-13 and UNKBAND instead of the various
  imager channel information)

I fixed the problem in the creation of the UNIWISC imagery Product IDs
this morning in time for the broadcast of the 14:45Z set.  At this
point, existing GEMPAK and McIDAS 'pqact' actions would start saving
the files again since the patterns used in the 'pqact' actions would
once again match the Product IDs for the GOES-East products.

If you have a local archive of the Unidata-Wisconsin images, and want
to recover the UNIWIS images that you missed, I will send you the access
information for the rolling archive maintained on the Unidata machine
hosted in the UW/SSEC Data Center.  Please let us know if you need/want
this information.

Cheers,

Tom

>From: Pete Pokrandt [mailto:address@hidden]
>Sent: Tuesday, December 16, 2008 10:00 AM
>To: Market, Patrick S.
>Cc: address@hidden
>Subject: Re: [gembud] FW: GOES 12 outage, GOES 13 changes for GEMPAK
>
>Market, Patrick S. wrote:
>
>Perhaps it's because of college finals that the traffic on this has been
>so light, but for those with an IDD feed, is there a change that must
>also be made to the 'pqact.conf' file?  I have looked at ours here at
>MU, and it should accept whatever comes down the pike, but so far, it
>seems that we have received no GOES-13 imagery.
>
>Pat
>
>Pat,
>
>I didn't change anything in my pqact file. Since the GOES-13 imagery is
>being sent out in the GOES-EAST sector, it should "just work".
>
>Here's what I have in my pqact for GOES-EAST sectors, I can send you the
>rest too if you'd like.
>
>#
># EAST-CONUS
>#
># png'd
>NIMAGE  TIGE01 .... ([0-3][0-9])([0-2][0-9])([0-5][0-9])        FILE
>/data/gemdata/sat/EAST-CONUS/1km/VIS/VIS_(\1:yy)(\1:mm)\1_\2\3
>NIMAGE  TIGE02 .... ([0-3][0-9])([0-2][0-9])([0-5][0-9])        FILE
>/data/gemdata/sat/EAST-CONUS/4km/IR/IR_(\1:yy)(\1:mm)\1_\2\3
>NIMAGE  TIGE04 .... ([0-3][0-9])([0-2][0-9])([0-5][0-9])        FILE
>/data/gemdata/sat/EAST-CONUS/4km/IR4/IR4_(\1:yy)(\1:mm)\1_\2\3
>NIMAGE  TIGE05 .... ([0-3][0-9])([0-2][0-9])([0-5][0-9])        FILE
>/data/gemdata/sat/EAST-CONUS/4km/WV/WV_(\1:yy)(\1:mm)\1_\2\3
>NIMAGE  TIGE06 .... ([0-3][0-9])([0-2][0-9])([0-5][0-9])        FILE
>/data/gemdata/sat/EAST-CONUS/8km/IR13/IR13_(\1:yy)(\1:mm)\1_\2\3
>
>Pete
>
>Dr. Patrick S. Market
>Associate Professor of Synoptic Meteorology
>Dept. of Soil, Env. & Atmospheric Sciences
>University of Missouri
>331 ABNR
>Columbia, MO  65211
>573-882-1496 (V)