[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[McIDAS #ZEN-523905]: New radar stuff



Hi Rick,

re:
> I don't recall if I ever asked you this question.  Is there a reason
> that you did not use the same raw-dbz-brit conversion?  If we did, all
> of our enhancements would have remained the same.

The raw to dBz conversion is defined in the Level II ICD, and they are
different for the "low resolution" (e.g., NxR) and "high resolution"
(e.g., NxQ) products.  I commented previously that adjusting the raw-dBz
mapping so that there was a match to the old products might be possible,
but it would open up the possibility of unintended errors.  On top of that,
it looks like the Weather Service will be adopting a new set of enhancements
for the "high resolution" products, and I feel that it would be wise for
McIDAS displays of those same products look like other displays of the
same products.

Cheers,

Tom
--
****************************************************************************
Unidata User Support                                    UCAR Unidata Program
(303) 497-8642                                                 P.O. Box 3000
address@hidden                                   Boulder, CO 80307
----------------------------------------------------------------------------
Unidata HomePage                       http://www.unidata.ucar.edu
****************************************************************************


Ticket Details
===================
Ticket ID: ZEN-523905
Department: Support McIDAS
Priority: Normal
Status: Closed