Simon,

How is the pqact(1) process on the downstream host being executed? Is it 
executed via an EXEC entry in the downstream LDM's configuration-file?

> My Ldm version is 6.12.9
> 
> Upstream transfer file to downstream via ldmsend
> Downstream save file to local disk by setting pqact.conf's  FILE function
> But downstream's pqact will write file in 10 min
> When i set pqact time offset to 3600 and then downstream's pqact will write
> file immediately
> 
> The system time in downstream is later than upstream by 10 min
> ex:
> upstream : 2016/10/04/10:20
> downstream:2016/10/04/10:30
> 
> Does Ldm compare upstream system time with downstream system time?
> Shall i use the time offset when downstream is later than upstream?


Regards,
Steve Emmerson