[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[IDD #LRB-829354]: Issues with product-queue



Hi Connor,

re:
> Also, just a quick question, will the full volume scan be broken up by the
> various scan layers? Such as 1 degree etc, or is it just condensed and
> processed into one large volume in one file?

The processing which I setup on Thursday evening recombines all of the pieces
back into a full volume scan.

I meant to send you a note about the processing setup being finished
yesterday (Friday), but a variety of things prevented me from getting
back to you.

NB: when I logged on your machine this morning, I noticed that the
LDM was not running.  Review of the LDM log file (~ldm/logs/ldmd.log)
shows that the LDM was indicating that the file system had filled-up
and someone/something had stopped the LDM:

 ...

Aug 22 16:37:12 MI-RM201A-03L pqact[11781] ERROR: unio_put(): write() error: 
"data/nexrad/level2/KFSD/20140822/.tmp/KFSD_20140822_223414": No space left on 
device
Aug 22 16:37:12 MI-RM201A-03L pqact[11781] ERROR: [filel.c:307] Deleting failed 
FILE entry "data/nexrad/level2/KFSD/20140822/.tmp/KFSD_20140822_223414"
AAug 22 16:38:14 MI-RM201A-03L pqact[11781] ERROR: unio_put(): write() error: 
"data/nexrad/level2/KFSD/20140822/.tmp/KFSD_20140822_223726": No space left on 
device
Aug 22 16:38:14 MI-RM201A-03L pqact[11781] ERROR: [filel.c:307] Deleting failed 
FILE entry "data/nexrad/level2/KFSD/20140822/.tmp/KFSD_20140822_223726"
Aug 22 16:38:14 MI-RM201A-03L ldmd[11779] NOTE: Exiting
Aug 22 16:38:14 MI-RM201A-03L ldmd[11779] NOTE: Terminating process group
Aug 22 16:38:14 MI-RM201A-03L idd.unidata.ucar.edu[11785] NOTE: Exiting
Aug 22 16:38:14 MI-RM201A-03L idd.meteo.psu.edu[11784] NOTE: Exiting
Aug 22 16:38:14 MI-RM201A-03L idd.tamu.edu[11783] NOTE: Exiting
Aug 22 16:38:14 MI-RM201A-03L pqact[11781] NOTE: Exiting
Aug 22 16:02:02 MI-RM201A-03L rtstats[11782] message repeated 14 times: [ 
ERROR: rtstats.unidata.ucar.edu: NULLPROC failure: RPC: Timed out]
Aug 22 16:38:14 MI-RM201A-03L rtstats[11782] NOTE: Exiting
Aug 22 16:38:15 MI-RM201A-03L pqact[11781] NOTE: Behind by 0.465735 s

This brings up the next thing to be done that I was going to discuss with
you: setting up scouring of data files so that your file system wouldn't
fill.  I apologize for not getting back to you yesterday to raise this
issue!

Given that the procedure for recombining NEXRAD Level II pieces back
into full volume scans is now setup, what additional things do you
want help on getting setup?

Cheers,

Tom
--
****************************************************************************
Unidata User Support                                    UCAR Unidata Program
(303) 497-8642                                                 P.O. Box 3000
address@hidden                                   Boulder, CO 80307
----------------------------------------------------------------------------
Unidata HomePage                       http://www.unidata.ucar.edu
****************************************************************************