Previous: Trajectory Display Next: Storm Tracks Table of contents Frames User guide
Unidata IDV Workshop for version 3.0u1 > Accessing and Displaying Data > Trajectory Data

3.10.1 Trajectory Point Display
Trajectory data can be displayed as individual point observations.
  1. If you do not have track data loaded see Trajectory Display.
  2. For performance reasons we want to subset the point data.
    • Right click on the track.nc entry in the Data Sources section.
    • Select Subset Point Data
    • Select all fields under Current Fields by clicking in the list and pressing Control-A.
    • Remove all selected fields by pressing Remove
    • Select the fields of interest. e.g., Altitude down to Dew/Frost Point Temperature with successive Control-clicks or Shift-Clicks.
    • Press Add
    • Press OK
  3. Create the Point Data Plot display.
    • In the Fields panel select the Point Data field.
    • In the Displays select Point Data Plot and press Create Display
    • When the IDV asks if you want to see all of the times select No.
    • Change the Station Model used to be Airplane
  4. Change the track time display
    • Bring up the display control window for the Track display.
    • Press Time Mode Change button.
    • For End Time choose From Animation Time
    • For Start Time choose Relative to End Time
    • Change the Offset for the start time to be -30 minutes.
  5. Turn on animation.
  6. For the point display change the Station Model used to be TrackDewpoint

 


Previous: Trajectory Display Next: Storm Tracks Table of contents Frames User guide